fix TerraSAR-X parameter bugs
fixed bugs in getting range bandwidth, chirp slope, pulse duration and range sampling frequencyLT1AB
parent
0fac7ff930
commit
3aa234c515
|
@ -171,8 +171,23 @@ class TerraSARX(Sensor):
|
||||||
instrument.setIncidenceAngle(incidenceAngle)
|
instrument.setIncidenceAngle(incidenceAngle)
|
||||||
instrument.setPulseRepetitionFrequency(prf)
|
instrument.setPulseRepetitionFrequency(prf)
|
||||||
instrument.setRangePixelSize(rangePixelSize)
|
instrument.setRangePixelSize(rangePixelSize)
|
||||||
|
|
||||||
|
|
||||||
|
#Cunren Liang, 2015
|
||||||
|
#the chirp bandwidth extracted before is definetely wrong
|
||||||
|
#I re-extract it here.
|
||||||
|
rangeSamplingFrequency = float(self.grab_from_xml('instrument/settings/RSF'))
|
||||||
|
chirpPulseBandwidth = float(self.grab_from_xml('instrument/settings/rxBandwidth'))
|
||||||
|
# this is not a correct value, TSX product does not provide pulse length
|
||||||
|
rangePulseLength = 1
|
||||||
|
#print("\n\n\n\n\n\n\n\n{0}\n\n\n\n\n\n\n\n\n".format(rangeSamplingFrequency))
|
||||||
|
#print("\n\n\n\n\n\n\n\n{0}\n\n\n\n\n\n\n\n\n".format(chirpPulseBandwidth))
|
||||||
|
|
||||||
|
|
||||||
#jng no sampling rate extracted before.
|
#jng no sampling rate extracted before.
|
||||||
instrument.setRangeSamplingRate(1/rowSpacing)
|
#instrument.setRangeSamplingRate(1/rowSpacing)
|
||||||
|
#the upper setting should be wrong, I change it. Cunren Liang, 2015
|
||||||
|
instrument.setRangeSamplingRate(rangeSamplingFrequency)
|
||||||
instrument.setPulseLength(rangePulseLength)
|
instrument.setPulseLength(rangePulseLength)
|
||||||
instrument.setChirpSlope(chirpPulseBandwidth/rangePulseLength)
|
instrument.setChirpSlope(chirpPulseBandwidth/rangePulseLength)
|
||||||
#instrument.setRangeBias(0)
|
#instrument.setRangeBias(0)
|
||||||
|
|